<Error>
<ErrorNumber>4021</ErrorNumber>
<ErrorFamily>Messaging</ErrorFamily>
<ErrorMessage>
MSG: Invalid list entry number sent - Possible version incompatabilities
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>All</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
The workstation software version and the firmware version are likely not compatible.  Check the
workstation release notes for the required firmware version.  If this is not a problem, this error is due to a
firmware or workstation software bug.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Record error message and contact Creo Service
</text></DescriptionText>
</OperatorAction>
<Cause>
Workstation software and firmware incompatible.
</Cause>
<Cause>
Workstation software or firmware bug
</Cause>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:32:23 2008 PST
</Updated>
<Links>
</Links>
</Error>